…Transformer - 208Y Three Phase - 208Y 3-Phase Primary - 240V 3-Phase Secondary *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Rating: 25 KVAEnclosure Type: Heavy Duty Ventilated NEMA Type 3RTransformerPhase: Three…
…NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: The MT-BBT-208D-240D-3P-62.5A buck and boost transformer is a three phase unit with a 25.5kVA rating and a primary voltage of 208V AC with 70.8 amps available on the primary…
…used to develop a three phase, four wire wye circuit from a three phase, three wire delta circuit.• Cannot be used in a closed delta connection.• Should not be used to correct for voltage drop on a long circuit run where the load demand fluctuates.• Cannot be used to create a 240/120V, single phase…
…MT-BBT-208V-240V-23.4A buck and boost transformer is a single phase unit with a 5.53 KVA rating and a primary voltage of 208 AC using a maximum of 26.6 amps on the primary side. This step-up transformer has a secondary voltage of 240 and provides up to 23.4 amps available on the secondary side.…
…FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: With a transformer rating of 12.39 kVA, the MT-BBT-208D-229D-3P-31.25A buck and boost transformer is a three phase unit with a primary voltage of 208V AC and 34.41 amps on the input…
…FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS*Transformer Features: With a transformer rating of 19.1 kVA, the MT-BBT-208D-236D-3P-46.9A buck and boost transformer is a three phase unit with a primary voltage of 208V AC and 53.1 amps on the input side.…
…used to develop a three phase, four wire wye circuit from a three phase, three wire delta circuit.• Cannot be used in a closed delta connection.• Should not be used to correct for voltage drop on a long circuit run where the load demand fluctuates.• Cannot be used to create a 240/120V, single phase…
15 kVA Transformer - 208 Wye Primary - 240/120V 4-Wire Secondary - Aluminum Windings*PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS*This 208Y3Phase Energy Efficient transformer is powerful, reliable and designed with the environment in…
…bring 208V three phase power to the NEMA 3R 600-amp 208V three phase primary disconnect, which contains three 450-amp time delay fuses protecting the 150 KVA transformer. The NEMA 3R 150 KVA transformer steps up 208V three phase power to 480V three phase and passes the current to the secondary…
…FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS*Transformer Features: With a transformer rating of 9.57 kVA, the MT-BBT-208D-236D-3P-23.4A buck and boost transformer is a three phase unit with a primary voltage of 208V AC and 26.6 amps on the input side.…
…grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~~Please check all motor loads for dual rated motors that will work 208 or 240. ~~ Specifications / Additional Information MGS-150K-2X120.20-4X208.50-4X208.1002P-4X208.1003P Ratings Line In: 480 VAC Three Phase…
…(blue, red, black, green) brings in 208Y three phase power to the 2,500-amp 240-600V primary disconnect, which is fused at 2,500 amps, to the NEMA 3R 750 KVA transformer. The transformer converts 208Y three phase power to 480Y/277 three phase and passes the current to the secondary disconnect. The…
…used to develop a three phase, four wire wye circuit from a three phase, three wire delta circuit.• Cannot be used in a closed delta connection.• Should not be used to correct for voltage drop on a long circuit run where the load demand fluctuates.• Cannot be used to create a 240/120V, single phase…
…FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: With a transformer rating of 12.8 kVA, the MT-BBT-208D-236D-3P-31.3A buck and boost transformer is a three phase unit with a primary voltage of 208V AC and 35.4 amps on the input side.…
…phase converter is designed to convert single phase power to three phase power. This solid-state unit accepts a single phase input range of 208-250V and provides a three phase output range of 208-250V. Line (input) voltage equals load (output) voltage. Operators may use this smart phase converter to…
…is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~~Please check all motor loads for dual rated motors that will work 208 or 240. ~~ Specifications / Additional Information MPD-480-30K-480I-NO Power Transformer Ratings Line In: 480V Three Phase (customer…
…brings 240V AC power to the NEMA 3R 60-amp 240V three phase primary disconnect, which contains three 60-amp time delay fuses and passes 240V three phase through to the transformer. The NEMA 3R 15 KVA transformer converts 208V three phase power to 480V three phase and passes the current to the…
…to one 4100R9W receptacle for three phase240V equipment. Operation: A customer provided cord brings 480V three phase power to the NEMA 3R 60-amp 480V three phase primary disconnect, which contains three 50-amp time delay fuses and passes 480V three phase through to the transformer. The NEMA 3R 30…
…phase converter is designed to convert single phase power to three phase power. This solid-state unit accepts a single phase input range of 208-250V and provides a three phase output range of 208-250V. Line (input) voltage equals load (output) voltage. Operators may use this smart phase converter to…
…three phase electrical current to three phase 208/120V AC. This unit provides operators the ability to safely tap into and distribute 120V AC and three phase208V AC power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO…
…work 208 or 240. ~~ Specifications / Additional Information MPD-6003-75K-250MB-120/208Y-10X120GFI Power Distribution System Ratings Line In: 600 VAC Three Phase (Customer supplied line-in cable) UL 1640 Portable Power-Distribution Equipment Disconnect: 100 amp 600V fused at 80 amps NEMA 3R Indoor…
…amp receptacles and 208Y VAC available via 1ea twist lock L21-30R. Main power to the 75 KVA transformer is protected by a fused 3Phase 60 amp NEMA 3R main disconnect. Power is routed from the transformer to a 3phase 250A Main Circuit panel board. The transformer is mounted to a 1/8” thick diamond…
…to native power sources. Operation: The customer provided line-in cord brings 480V three phase power to the 30-amp 480V 3-phase fused disconnect, which contains three 30-amp time delay fuses protecting the 30 KVA transformer. The NEMA 3R transformer converts 480V three phase power to three phase…
…to operate with 480 3P which it then steps down to 120V single phase and 240 (208Y) VAC 3phase. This transformer makes 120VAC available via 6 GFCI protected 120 V receptacles and 208Y VAC available via two GFCI protected 240VAC outlets. Click Photo to Enlarge Click Photo to Enlarge Click Photo to…
…this rotary phase converter to power machines that require three phase power in locations where only single phase power is available. The MTPC-RB-208.240-1P-3HP-3P rotary phase converter is suitable for converting single phase power to three phase power at 208-245V (input/output). This 3HP (2.2 kW)…
…The unit supports complete phase power protection in the event of failure. The MTPC-RB-208.240-1P-50HP-3P-N3R is a NEMA 3R rated enclosed model, making it suitable for indoor and outdoor environments. This level of protection allows the rotary phase converter to withstand the ingress of solid…
…Rotary Phase Converter Ratings/Approvals Unit Type: Rotary Phase Converter NEMA 3RPhase Conversion: Single Phaseto Three Phase Built-in Motor Starter Horse Power: 10 HP (7.5 kW 60 Hz) Start/Stop Push Button Switch Single Phase Voltage Input: 208-245V Phase Power Failure…
…rotary phase converter is designed to convert single phase power to three phase power. This unit accepts a single phase input range of 208-245V and provides a three phase output range of 208-245V. Operators may use this rotary phase converter to power machines that require three phase power in…
…rotary phase converter is designed to convert single phase power to three phase power. This unit accepts a single phase input range of 208-245V and provides a three phase output range of 208-245V. Operators may use this rotary phase converter to power machines that require three phase power in…
…side, operators connect to six CS6369 208V receptacles for their 208V equipment and a four ivory 5-20R GFCI receptacles for 120V equipment. Operation: The customer provided line-in cord brings 480V three phase power to the NEMA 4 stainless steel 200-amp 480V three phase main breaker panel with…
…(Maximum) Power Indicator Light Minimum Wire Input: 2/0 AWG Made in the USA Idle Amps: 7.42 Three Phase Voltage Output: 208-245V Output Amps: 80 Voltage Balance: 2-5% Minimum Wire to Generator/Load: 3 AWG Special Orders- Requirements Form Factor: Rectangular Enclosure, Cylindrical Idler w/ Four Legs…
…rotary phase converter is designed to convert single phase power to three phase power. This unit accepts a single phase input range of 208-245V and provides a three phase output range of 208-245V. Operators may use this rotary phase converter to power machines that require three phase power in…
…rotary phase converter is designed to convert single phase power to three phase power. This unit accepts a single phase input range of 208-245V and provides a three phase output range of 208-245V. Operators may use this rotary phase converter to power machines that require three phase power in…
…rotary phase converter is designed to convert single phase power to three phase power. This unit accepts a single phase input range of 208-245V and provides a three phase output range of 208-245V. Operators may use this rotary phase converter to power machines that require three phase power in…
…digital phase converter is designed to convert single phase power to three phase power. This solid-state unit accepts a single phase input range of 208-250V and provides a three phase output range of 208-250V. Operators may use this smart phase converter to power machines that require three phase…
…digital phase converter is designed to convert single phase power to three phase power. This solid-state unit accepts a single phase input range of 208-250V and provides a three phase output range of 208-250V. Operators may use this smart phase converter to power machines that require three phase…
…digital phase converter is designed to convert single phase power to three phase power. This solid-state unit accepts a single phase input range of 208-250V and provides a three phase output range of 208-250V. Operators may use this smart phase converter to power machines that require three phase…
…but have access to 480 3-phase or single phase power. A 30X30X12 NEMA 3R enclosure has access points for operators to tap the primary side of the transformer. Two sets of Ilsco blocks are provided for making high amp connections on the secondary side. This model supports up to3KVA with two sets of…
…phase power to the NEMA 3R 600-amp 600V three phase primary disconnect, which contains three 600-amp time delay fuses, and passes 480V three phase through to the transformer. The NEMA 3R 500 KVA transformer converts 480V three phase power to 480/415/240/208V three phase and passes the current to the…
…to native power sources. This unit is designed to operate with a 480V 3phase primary which it then steps down to 120V single phase and 240 (208Y) VAC. This transformer provides secondary power via 4 GFCI protected 120V receptacles and ten ADR1044 100 amp 4 wire 4 pole receptacles for 3phase 208Y.…
…repairs with 120 volt or 208Y VAC powered equipment. The operator provides line in cord that connects to a 400 amp fused ON/OFF disconnect switch which controls current to the 150 KVA, 480 Volt 3phase transformer with Nema 3r configuration. The transformer is mounted to a 1/8” thick diamond plate…
…used to develop a three phase, four wire wye circuit from a three phase, three wire delta circuit.• Cannot be used in a closed delta connection.• Should not be used to correct for voltage drop on a long circuit run where the load demand fluctuates.• Cannot be used to create a 240/120V, single phase…
…used to develop a three phase, four wire wye circuit from a three phase, three wire delta circuit.• Cannot be used in a closed delta connection.• Should not be used to correct for voltage drop on a long circuit run where the load demand fluctuates.• Cannot be used to create a 240/120V, single phase…
…FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: With a transformer rating of 43.1 kVA, the MT-BBT-208D-236D-3P-93.75A buck and boost transformer is a three phase unit with a primary voltage of 208V AC and 106.3 amps on the input…
…used to develop a three phase, four wire wye circuit from a three phase, three wire delta circuit.• Cannot be used in a closed delta connection.• Should not be used to correct for voltage drop on a long circuit run where the load demand fluctuates.• Cannot be used to create a 240/120V, single phase…
…used to develop a three phase, four wire wye circuit from a three phase, three wire delta circuit.• Cannot be used in a closed delta connection.• Should not be used to correct for voltage drop on a long circuit run where the load demand fluctuates.• Cannot be used to create a 240/120V, single phase…
…FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: With a transformer rating of 27.06 kVA, the MT-BBT-208D-250D-3P-62.5A buck and boost transformer is a three phase unit with a primary voltage of 208V AC and 75.12 amps on the input…
…sales@larsonelectronics.com to discuss your specific requirements. Specifications / Additional Information MT-ISX-1P-208V-7.5KVA-120.240V-N3R Isolation Transformer Ratings Phase: Single Phase Listed for United States and Canada Frequency: 60Hz ANN Cooling kVA: 7.5 IP24 Rated Primary Voltage: 208V…
…motors that will work 208 or 240. ~~ Specifications / Additional Information MPD-225K-200A-GFI.50.100.200-30K-100A-5X120.20 Power Distribution System Ratings Line In:480 VAC Three Phase UL 1640 Portable Power-Distribution Equipment Transformer 1: 225KVA - 480D to 480Y N3R NEMA 3R Indoor or Outdoor…
…OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: With a transformer rating of 7.5kVA, the MT-1P-208V-7.5KVA-240V-N3R transformer is a single phase unit with a primary voltage of 208V AC. It also provides a secondary voltage of 240V AC. Featuring…
…OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: With a transformer rating of 25kVA, the MT-1P-208V-25KVA-240V-N3R transformer is a single phase unit with a primary voltage of 208V AC. It also provides a secondary voltage of 240V AC. Featuring…
…OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: With a transformer rating of 15kVA, the MT-240V-15KVA-208V transformer is a single phase unit with a primary voltage of 240V AC. It also provides a secondary voltage of 208V AC. Featuring robust…
…OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: With a transformer rating of 7.5kVA, the MT-240V-7.5KVA-208V transformer is a single phase unit with a primary voltage of 240V AC. It also provides a secondary voltage of 208V AC. Featuring robust…
…OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: With a transformer rating of 25kVA, the MT-240V-25KVA-208V transformer is a single phase unit with a primary voltage of 240V AC. It also provides a secondary voltage of 208V AC. Featuring robust…
…NEMA 3R 45 KVA transformer converts 480V three phase power to 240/208-120V three phase and passes the current to the secondary panel. The secondary side of the transformer feeds a NEMA 3R 125-amp rated 240/208-120V three phase main lug panel. This secondary panel contains three 50-amp 240V breakers…
…MT-BBT-240-208-100A buck and boost transformer is a single phase unit with a 22.1 KVA rating and a primary voltage of 236 AC using a maximum of 93.7 amps on the primary side. This step-down transformer has a secondary voltage of 208 and provides up to 106 amps available on the secondary side.…
…power distribution system is designed to enable operators to connect to 480V three phase primary voltage and step it down to 240/208-120V three phaseto operate lights and equipment. Operators can connect to 480V power sources using the 20` of included #3 Type SOOW cable on the input side. On the…