Vast Inventory for Fast Shipping. Custom Builds Available, Rentals and Sales. Most items in stock for fast shipping!! UPS Ship Map Credit cards & Paypal Accepted
…- 480V 3 Phase - 480V Delta Primary - 600V Delta Secondary - NEMA 2 Enclosure *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Rating: 75kVATransformer Phase: Three PhasePrimary Voltage: 480V DeltaSecondary Voltage: 600V…
…600V three phase power to the NEMA 3R 100-amp 600V three phase primary disconnect, which is fused at 80-amps, and passes power to another primary disconnect, which is a NEMA 3R, 30-amp 600V three phase unit fused at 25 amps. Power is passed to a NEMA 3R 75 KVA transformer, converting 575V to480V AC…
…substation gives operators the ability to draw input voltage from 480V power sources through a 600 amp main breaker. The unit`s 112.5 KVA transformer then steps down the input voltage to 208Y/120V. On the secondary panel side, operators can plug in up to four 20-amp 120V devices into the GFCI…
…#2 Type W cable brings 480V single phase power to the 480V single-phase 200-amp fusible disconnect fused at 175 amps and passes power to the transformer. The NEMA 3R 75KVA transformer converts 480V single-phase power to 120/240V single phase 60Hz and passes the current to the secondary panel. The…
…The mast is extended to its full height using an included 600 lbs hand winch with 3/16" galvenized cable. Included with this light tower is one of our wet area suitable GAU-LTL-400W-LED high output LED fixtures producing a combined total of approximately 60,000 lumens at 480 watts. The light head…
…line-in cord brings 480V three phase power to the NEMA 3R 600-amp 600V three phase primary disconnect, which contains three 600-amp time delay fuses, and passes 480V three phase through to the transformer. The NEMA 3R 500 KVA transformer converts 480V three phase power to 480/415/240/208V three…
…operates on 480V AC and includes an explosion proof 3-pole 4-wire cord cap. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO LIGHT MASTS OR LIGHT TOWERS* Larson Electronics’ LM-30-3S-HAL-4X150LED-RT-480V telescoping steel light tower mast is designed to allow operators to quickly and safely…
…alternative to 1000 watt metal halide lamps that uses little power and can withstand rugged use and abusive conditions. The GAU-HB-600W-LED-SS-480V LED light from Larson Electronics produces 60,000 lumens of high intensity light while drawing only 480 watts at 1.25 amps from a 480 volt electrical…
…line-in cord brings 480V three phase power to the NEMA 3R 600-amp 600V three phase primary disconnect, which contains three 600-amp time delay fuses, and passes 480V three phase through to the transformer. The NEMA 3R 500 KVA transformer converts 480V three phase power to 480/415/240/208V three…
Made in the USA *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Panel NEMA 3R 600A Main Breaker 480V Three Phase Panel 4 X 125A 480V 3 Phase Breakers Structure Wheeled Dolly Cart UL 1640 Portable Power-Distribution Equipment NEMA 3R…
…that brings 480V three phase power to the 600 amp three phase 480 volt main breaker three phase, Nema 3R panel. Eight 480V 3-wire, 4-pole 60 amp receptacles are protected by eight 60 amp breakers within the three phase panel. A double pole 200-amp breaker protects the 112.5 KVA 480 volt to 120/240…
…cable that brings 480V three phase power to the 600 amp three phase 480V Nema 3R breaker panel. Four 125 amp breakers protect four 3 wire 4 pole 480V receptacles with mating plugs. A 125 amp breaker protects the Nema 3R configured 75KVA transformer. The 480V three phase to 120/240V 75KVA transformer…
…cord brings 480V power to the NEMA 3R 400-amp 600V three phase primary disconnect, which contains three 50-amp time delay fuses protecting the 225 KVA transformer, and passes 480V three phase through to the transformer. The NEMA 3R 225 KVA transformer converts 480V three phase power to 208Y/120V and…
…cord brings 480V power to the NEMA 3R 400-amp 600V three phase primary disconnect, which contains three 50-amp time delay fuses protecting the 225 KVA transformer, and passes 480V three phase through to the transformer. The NEMA 3R 225 KVA transformer converts 480V three phase power to 208Y/120V and…
…480V three phase power to the NEMA 3R 400-amp 600V three phase primary disconnect, which contains three 400-amp time delay fuses, and passes 480V three phase through to the transformer. The NEMA 3R 300 KVA transformer converts 480V three phase power to 208Y/120V three phase and passes the current to…
…480V three phase power to the NEMA 3R 400-amp 600V three phase primary disconnect, which contains three 400-amp time delay fuses, and passes 480V three phase through to the transformer. The NEMA 3R 300 KVA transformer converts 480V three phase power to 208Y/120V three phase and passes the current to…
…with a 63-amp 480V pin/sleeve cord cap brings 480V three phase power to the NEMA 3R 200-amp 600V three phase primary disconnect, which contains three 175-amp time delay fuses, and passes 480V three phase through to the transformer. The NEMA 3R 112.5 KVA transformer converts 480V three phase power to…
…480V three phase power to the NEMA 3R 60-amp 600V three phase primary disconnect, which contains three 60-amp time delay fuses and passes 480V three phase through to the transformer. The NEMA 3R 45 KVA transformer converts 480V three phase power to 240/208-120V three phase and passes the current to…
…LED alternative to 1500 watt metal halide lamps that uses little power and can withstand rugged use and abusive conditions. The GAU-LTL-500W-LED-600V LED light from Larson Electronics produces 60,000 lumens of high intensity light while drawing only 480 watts at 0.8 amps from a 600 volt electrical…
…480V three phase power to the NEMA 3R 60-amp 480V three phase primary disconnect, which contains three 50-amp time delay fuses and passes 480V three phase through to the transformer. The NEMA 3R 30 KVA transformer converts 480V three phase power to 240/208-120V three phase and passes the current to…
…brings 480V three phase power to the NEMA 3R 30-amp 480V three phase primary disconnect, which contains two 15-amp time delay fuses and passes 480V three phase through to the transformer. The NEMA 3R 3 KVA transformer converts 480V three phase power to 120/240V single phase and passes the current to…
…bring 480V three phase power to the 60-amp automatic transfer switch on the primary side, which can accept two different power sources, and passes power to the transformer. The NEMA 3R 45 KVA transformer converts 480V three phase power to 208Y/120V three phase and passes the current to the secondary…
…brings 480V three phase power to the NEMA 3R 30-amp 480V three phase primary disconnect, which contains two 15-amp time delay fuses and passes 480V three phase through to the transformer. The NEMA 3R 3 KVA transformer converts 480V three phase power to 120/240V single phase and passes the current to…
…brings 480V three phase power to the NEMA 3R 30-amp 480V three phase primary disconnect, which contains two 15-amp time delay fuses and passes 480V three phase through to the transformer. The NEMA 3R 3 KVA transformer converts 480V three phase power to 120/240V single phase and passes the current to…
…480V equipment. All receptacles are protected by weatherproof covers. Operation: A 20` 2/3 Type W cord brings 208V three phase power to the 200-amp 208V disconnect, which is fused at 150 amps, and passes power to the transformer. The NEMA 3R 45 KVA transformer converts 208V three phase power to480V…
…cord brings 480V power to the NEMA 3R 60-amp 480V three phase primary disconnect, which contains three 45-amp time delay fuses protecting the 30 KVA transformer, and passes 480V three phase through to the transformer. The NEMA 3R 30 KVA transformer converts 480V three phase power to 208Y/120V and…
…bring 480V three phase power to the 60-amp automatic transfer switch on the primary side, which can accept two different power sources, and passes power to the transformer. The NEMA 3R 45 KVA transformer converts 480V three phase power to 208Y/120V three phase and passes the current to the secondary…
…substation converts three phase, 480V AC electrical current to single phase 240V and 120V AC via an encapsulated Class I, Division 2 15KVA transformer (480V-3P to 120/240V-1P 60Hz). 20` of 10/4 SOOW line-in cable is included to connect the substation to a primary 480V primary power supply. A Class…
MADE IN THE USA This Larson Electronics power distribution system takes 480 volt 3-phase power and converts it to 400 amps of 120/208Y, available via one 400-amp Veam Power Lock connector. 120/208Y is also available via a 200-amp sub panel with protection for a L15-50 receptacle, a L6-50 receptacle…
MADE IN THE USA This Larson Electronics power distribution system takes 480 volt 3-phase power and converts it to 400 amps of 120/208Y, available via one 400-amp Veam Power Lock connector. 120/208Y is also available via a 200-amp sub panel with protection for a L15-50 receptacle, a L6-50 receptacle…
…distribution system requires operators to provide line-in cable connections to the primary 600V 400-amp J-15 Series Cam-lok male inputs. The included disconnect protects the 150kVA NEMA 3R 480Vto 208Y/120V transformer. The transformer passes power to the 400 amp main breaker, 18 circuit, 208Y/120V…
…line-in cord brings 480V three phase power to the 60-amp 480V 3-phase primary disconnect, which contains three 60-amp time-delay fuses protecting protecting the 45 KVA transformer. The NEMA 3R 45 KVA transformer converts 480V three phase power to 208Y/120V and passes the current to the secondary…
…600lbs Toll Free: 1-800-369-6671 Max Primary OCP: 60A @ 480V Intl: 1-903-498-3363 Max Secondary OCP: 150A @ 208V E-mail: sales@larsonelectronics.com *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to…
…cord brings 480V three phase power to the 200-amp 480V three-phase primary disconnect, which contains three 125-amp time-delay fuses protecting the 75 KVA transformer. The NEMA 3R 75 KVA transformer converts 480V three phase power to 208Y/120V three phase and passes the current to the secondary…
…portable power distribution system is designed to enable operators to connect to480V three phase primary voltage and step it down to 208Y/120V three phase to operate lights and equipment. Operators can connect to480V power sources using the 20` of included 2/4 Type-W…
…portable power distribution system is designed to enable operators to connect to480V three phase primary voltage and step it down to 240/208-120V three phase to operate lights and equipment. Operators can connect to480V power sources using the 20` of included #3 Type…
…350AWG Type W line-in cord brings 480V three-phase power to the NEMA 3R 400-amp 480V three-phase main circuit breaker panel, which contains four 50-amp 480V breakers, protecting four 50-amp twist-lock California-style CS8169 480V receptacles, and passes power through to the transformer. Protected by…
…Electronics is IP65 rated, vapor proof, and uses three 48 inch LED light heads to produce a combined 57,600 lumens of light with 360° coverage while drawing only 480 watts.***PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO THIS HAZARDOUS LOCATION LIGHT FIXTURE***The WAL-3X160LED-4-100 work…
…alternative to native power sources. Operation: 75` 4/4 Type-W line-in cord brings 480V three phase power to the 100-amp 480V 3-phase fused disconnect, which contains three 100-amp time delay fuses protecting the 75 KVA transformer. The NEMA 3R transformer converts 480V three phase power to…
…Sixteen 480V 3-wire 4-pole receptacles are protected by six 40-amp breakers, four 30-amp breakers, four 100-amp breakers and two 60-amp breakers. A separate 480V 200-amp disconnect with separate enclosure in included (no associated outlet). The 480V primary panel feeds the 75 KVA 480Vto 120/208Y…
…operators the ability to power their 480 volt and 120 volt equipment from a single system. On the primary side, operators connect 480 volt line-in power using a customer provided cord and to one 100-amp 4100R7W 480V receptacle and seven 60-amp 460R7W 480V receptacles for 480V equipment. On the…
…cord brings 480V three phase power to the NEMA 3R 200-amp 600V three phase primary disconnect, which contains three 200-amp time delay fuses, and passes power through to the transformer. The NEMA 3R 150 KVA transformer converts 480Vto 208Y/120V three phase and passes the current to the secondary…
…with a 100-amp 600VAC rated APJ10487 cord cap brings 480V three phase power to a NEMA 3R 30-amp 480V three-phase primary disconnect, which contains three 30-amp time delay fuses protecting one, 30-amp 600VAC rated AR342 receptacle and 480V single phase power to a NEMA 3R 60-amp 480V single phase…
…Voltage: 480V 3PH UL 1640 Portable Power-Distribution Equipment Primary Disconnect: 480V600A Fused @ 450A N3R NEMA 3R Indoor or Outdoor Use Primary Panel: - Made in the USA Primary Breakers: - Primary Receptacles: - Primary Protection: Disconnect Switch Transformer: 150 KVA 480Vto 208Y 3PH N3R…
…brings 480V three phase power to the NEMA 3R 30-amp 480V three phase primary disconnect, which contains two 15-amp time delay fuses and passes 480V three phase through to the transformer. The NEMA 3R 3 KVA transformer converts 480V three phase power to 120/240V single phase and passes the current to…
…to discuss your specific requirements. Specifications / Additional Information MPD-480X6-112.5K-12X120-4X240-CWRF-V3 Power Transformer Line-In Cord: 20` 350KCMIL Type W Max OCP Primary: 600A @ 480V Line-In Cord Cap: Customer Provided Max OCP Primary: 200A @ 240V Primary Voltage: 480V 3PH UL 1640…
…terminated with a 60-amp 600V rated NPJ6484 cord cap brings 480V three phase power to the NEMA 3R 60-amp 480V three phase primary disconnect, which contains two 40-amp time delay fuses, and passes power through to the transformer. The NEMA 3R 15 KVA transformer converts 480Vto 120/240V single phase…
…us at 1-800-369-6671 or sales@larsonelectronics.com to discuss your specific requirements. Specifications / Additional Information MPD-480.3P-4XCL-300K-800M-10XCL Power Transformer Line-In Cord: Customer Provided Max OCP Primary: 600A @ 480V Line-In Cord Cap: 690A Cam-Locks [Brown, Orange, Yellow,…
…600VAC rated APJ10377 cord cap brings 480V three phase power to a NEMA 3R 100-amp 480V three phase primary disconnect, which contains 100-amp time delay fuses protecting one, 100-amp 600VAC rated AR1031 receptacle. On the primary side, 480VAC three-phase is also distributed to a NEMA 3R 30-amp 480V…
…connect customer provided cables to the panel mounted cam-locks to energize equipment and systems requiring 480V three phase power. Cam Locks Cam Locks Disconnect Cam Lock Fuse Click Images to Enlarge Click Photo to Enlarge Click Photo to Enlarge Click Photo to Enlarge Protective Construction:…
…a CS8165C cord cap brings 480V three phase power to the 60-amp 480V 3-phase fused disconnect, which contains three 60-amp time delay fuses protecting the 75 KVA transformer. The NEMA 3R transformer converts 480V three phase power to 208/120V and passes the current to the secondary panel. The…
…W cord brings 480V three phase power to the 60-amp 480V three-phase fused disconnect, which contains three 60-amp time delay fuses, and passes power to the transformer. The NEMA 3R 45 KVA transformer converts 480V three phase power to 380V three phase 60 Hz and passes the current to a 60 HP 380V…
…blunt-cut end brings 480V three phase power to the 100-amp 480V three-phase fused disconnect, which contains three 100-amp time delay fuses, and passes power to the transformer. The NEMA 3R 75 KVA transformer converts 480V three phase power to 208Y/120V and passes the current to the secondary panel.…