Vast Inventory for Fast Shipping. Custom Builds Available, Rentals and Sales. Most items in stock for fast shipping!! UPS Ship Map Credit cards & Paypal Accepted
…/ Additional Information EPL-TSW-20A ExplosionProof Switch Ratings/Approvals Configuration: On/Off Switch Class1, Division 1 & 2, Groups C & D Dimensions: Class2, Divisions 1 & 2, Groups E, F, G Weight: 8 lbs Class 3, Divisions 1 & 2 Switch Style: 2-pole NEMA 7 (Groups C…
…ExplosionProof 3-Position Selector Switch - Maintained, Lock Out - Class I, II, Div1 & 2,Class Ratings/Approvals Unit Type: Factory Sealed Switch Class I, Div.1 & 2, Groups C, D Dimensions: 3.5"W x 5.88"H x 2.38"D Class II, Div.1, Groups E, F & G Voltage Rating: 600V AC Class II,…
…EPS-3PSW-MMS - ExplosionProof Factory Sealed 3-Position Selector Switch Ratings/Approvals Unit Type: Factory Sealed Switch Class I, Div.1 & 2, Groups C, D Dimensions: 3.5"W x 5.88"H x 2.38"D Class II, Div.1, Groups E, F & G Voltage Rating: 600V AC Class II, Div.2, Groups F & G…
…and equipment in hazardous locations. This explosionproof starter switch is ideal for operators seeking a high quality explosionproof starter switch rated for use in hazardous areas designated Class1 Division 1 and Class2 Division 1. This explosionproof switch is rated for 10 HP at 380-575V AC,…
…ExplosionProof Factory Sealed 2-Position Selector Switch - Class I, II, Div1 & 2 Ratings/Approvals Unit Type: Factory Sealed Switch Class I, Div.1 & 2, Groups C, D Dimensions: 3.89" x 4.43" x 5.06" Class I, Zones 1 & 2, Groups llB, lIA Voltage Rating: 600V AC Class II, Div.1 & 2,…
…EPS-25A-4W ExplosionProof Tumbler Switch Certifications - Compliance Unit Type: ExplosionProof Switch Class I, Div.1 & 2, Groups B, C, D Switch Type: Four-way Class II, Div.1, Groups E, F, G Dimensions: 3" x 4.69" x 6.13" Class II, Div.2, Groups F, G Weight: 3 lbs Class III Voltage…
…to zero any time during the countdown (example: after 10 minutes, reset back to zero). The explosionproof timer switch is designed for Class I, Division 1 and 2;Class2, Division 1 and 2; and Class III environments. The EXP-RT-DPST-MIN.60 is constructed of copper-free cast aluminum for superior…
…a dual pole single throw switch, which allows operators to set the timer to 30 minutes. The explosionproof timer switch is designed for Class I, Division 1 and 2;Class2, Division 1 and 2; and Class III environments. The EXP-RT-DPST-MIN.30 is constructed of copper-free cast aluminum for superior…
…ExplosionProof Dimmable Rotary Switch is UL approved Class I Division 1 & 2 Groups C & D, Class II Division 1 & 2 Groups E, F and G and Class III. This 0-10V dimmable explosionproof switch provides a safe and secure method for operators to adjust the brightness of explosionproof…
…ExplosionProof Dimmable Rotary Switch is UL approved Class I Division 2 Groups C & D, Class II Divisions 1 & 2 Groups E, F and G and Class III. This 0-10V dimmable explosionproof switch provides a safe and secure method for operators to adjust the brightness of explosionproof lights…
…EPSW-20A-OFO ExplosionProof Switch Ratings/Approvals Unit Type: ExplosionProof Selector Switch Class I, Divisions 1 & 2 Groups B, C, D Dimensions: 5.875" x 3.5" x 3.0625" Class II, Division 1 Groups E, F, G Weight: 3 lbs Class II, Division 2 Groups F, G Rated Voltage: 600V AC (Maximum) Class…
…ExplosionProof Selector Switch Ratings/Approvals Unit Type: ExplosionProof Selector Switch Class I, Divisions 1 & 2 Groups C,D Dimensions: 4" - L, 1.75" - Diameter Class I, Zones 1 & 2 Groups llB,llA Weight: 2 lbs Class II, Divisions 1 & 2 Groups E,F,G Voltage Rating: 600V AC Class III…
…Information EPS-PB10-MS-AT-V1 ExplosionProof Push Button Switch Features/Ratings Unit Type: ExplosionProof Push Button Momentary Switch Class I, Divisions 1 & 2 Groups C & D Dimensions: - Class II, Divisions 1 & 2 Groups E, F, G Weight: - Class III Voltage: 120-277V AC NEMA 7…
…4.16"D Class I, Zone 1, AEx de IIC T4/T5/T6 Gb Voltage Rating: 690V AC, 20A, 50-60Hz Class II, Division 2, Groups E, F, G Horsepower Rating: 2 HP Class II, Zone 2, Aex tb IIIC T4/T5/T6 Db IP66 Ambient Operating Temp Range: -50°C to +60°C Class III, Divisions 1 & 2 UV Protection: f1 II 2 G Ex de…
…ExplosionProof Switch Ratings/Approvals Type: Non-metallic ExplosionProof Switch Class I, Division 2, Groups A, B, C, D Dimensions: 31.6" x 37.68" x 33.28" Class I, Zone 1, AEx de IIC T4/T5/T6 Gb Voltage Rating: 690V AC, 20A, 50-60Hz Class II, Division 2, Groups E, F, G Horsepower Rating: 2 HP…
…4.16"D Class I, Zone 1, AEx de IIC T4/T5/T6 Gb Voltage Rating: 690V AC, 20A, 50-60Hz Class II, Division 2, Groups E, F, G Horsepower Rating: 2 HP Class II, Zone 2, Aex tb IIIC T4/T5/T6 Db IP66 Ambient Operating Temp Range: -50°C to +60°C Class III, Divisions 1 & 2 UV Protection: f1 II 2 G Ex de…
…Class I, Division 2, Groups A, B, C, D Dimensions: 3.95"W x 4.21"H x 4.16"D Class I, Zone 1, AEx de IIC T4/T5/T6 Gb Voltage Rating: 690V AC 50/60Hz Class II, Division 2, Groups E, F, G Amperage Rating: 20A Class II, Zone 2, Aex tb IIIC T4/T5/T6 Db IP66 Horsepower Rating: 2 HP Class III, Divisions 1…
…Class I, Division 2, Groups A, B, C, D Dimensions: 3.95"W x 4.21"H x 4.16"D Class I, Zone 1, AEx de IIC T4/T5/T6 Gb Voltage Rating: 690V AC 50/60Hz Class II, Division 2, Groups E, F, G Amperage Rating: 20A Class II, Zone 2, Aex tb IIIC T4/T5/T6 Db IP66 Horsepower Rating: 2 HP Class III, Divisions 1…
…Information EPL-SLSW-XL ExplosionProof Selector Switch Ratings/Approvals Unit Type: ExplosionProof Selector Switch Class I, Divisions 1 & 2 Groups B,C,D Dimensions: 5.31" - L, 1.25" - Diameter Class I, Zones 1 & 2 Groups llB,llA Weight: 2 lbs Class II, Divisions 1 & 2 Groups E,F,G…
…Contact 3-Position Selector Switch Class I, Division 2, Groups A, B, C, D Dimensions: 3.95"W x 4.21"H x 4.16"D Class I, Zone 1, AEx de IIC T4/T5/T6 Gb Voltage Rating: 690V AC, 20A, 50-60Hz Class II, Division 2, Groups E, F, G Horsepower Rating: 2 HP Class III Ambient Operating Temp Range: -50°C…
…ExplosionProof Switch - 60 Amps Ratings/Approvals Unit Type: ExplosionProof Non-fused Disconnect Switch Class I, Div.1 & 2, Groups B, C, D Dimensions: 5.75" x 8" x 6.3" Class l, Zones 1 & 2, Groups llB+ H2, llA Max Voltage: 600VAC Class II, Div.1 & 2, Groups E, F, G Amps: 60 Class…
…ExplosionProof Switch by Larson Electronics is a non-fused disconnect unit for motor circuits in hazardous locations. This device comes with the following explosionproof ratings: Class I, Div.1 & 2 (Groups B, C, D); Class l, Zones 1 & 2 (Groups llB+ H2, llA); Class II, Div.1 & 2…
…ExplosionProof Switch - 60 Amps Ratings/Approvals Unit Type: ExplosionProof Non-fused Disconnect Switch Class I, Div.1 & 2, Groups B, C, D Dimensions: 5.75" x 8" x 6.3" Class I, Zones 1 & 2, Groups llB+ H2, llA Max Voltage: 600VAC Class II, Div.1 & 2, Groups E, F, G Amps: 60 Class…
…meet your specific industry needs. Specifications / Additional Information EPSW-VPS-78PS-15A ExplosionProof Switch Features/Ratings Unit Type: ExplosionProof Pressure/Vacuum Switch Class I, Div1 & 2, Groups B,C,D Dimensions: - NEMA 4X Weight: - IP66 Voltage: 250V AC or 30V DC Amps: 15A @ 250V…
…Features/Ratings Unit Type: ExplosionProof Motor Starter Switch Class I, Div.1 & 2, Groups C,D Dimensions: 4.125" x 7.625" x 5.875" Class1, Zones 1 & 2, Groups llB, llA Weight: 2.55 lbs Class II, Div.1 & 2, Groups E,F,G Voltage: 460-575V AC Class III HP: 10 NEMA 7(C,D) 9(E,F,G)…
…Information EPS-PB10-MS-AT-V2 ExplosionProof Push Button Switch Features/Ratings Unit Type: ExplosionProof Push Button Momentary Switch Class I, Divisions 1 & 2 Groups C & D Dimensions: - Class II, Divisions 1 & 2 Groups E, F, G Weight: - Class III Voltage: 120-277V AC NEMA 7…
…your specific industry needs. Specifications / Additional Information HLSW-FDS-SS-16A-2X0.75 ExplosionProof Disconnect Switch Features/Ratings Unit Type: ExplosionProof Disconnect Switch Class I, Division 2 Groups A,B,C,D Dimensions: 11.8" x 9.9" x 5.9" Enclosure Type 3, 4, 4x Weight: - IP66 Rated…
Made in the USA Larson Electronics ExplosionProofExplosionProof GFI Cord Whip with inline switch. Class1 Division 1 and Class2 Division 1 Approved. The EPEXC-GFI-20O-ISL ExplosionProof cord whip allows operators to safely operate their explosionproof light or equipment cords beyond the…
Made in the USA Larson Electronics ExplosionProofExplosionProof GFI Cord Whip with inline switch. Class1 Division 1 and Class2 Division 1 Approved. The EPEXC-GFI-20O-ISL-100-1523 ExplosionProof cord whip allows operators to safely operate their explosionproof light or equipment cords beyond…
…Larson Electronics EXP-LS-RH-2P ExplosionProof Limit Switch is designed for Class I, Division 1 and Class II, Division 1 industrial facilities. This snap-action device is compatible with 600V AC/250V DC and contains two, NC-NO contacts. The 2-pole explosionproof limit switch is constructed of…
…body, and carries a NEMA 4X rating. This explosionproof starter switch is ideal for operators seeking a high quality explosionproof starter switch rated for use in hazardous areas designated Class1 Division 1 and Class2 Division 1. This explosionproof switch is rated at 10 amps. The entire unit…
…Switch - Maintained Features/Ratings Unit Type: ExplosionProof Maintained Switch Class I, Div.1 & 2, Groups C,D Dimensions: - Class1, Zones 1 & 2, Groups llB, llA Weight: - Class II, Div.1 & 2, Groups E,F,G Voltage: 480V AC 3PH Class III Amps: 20A Rated NEMA 7(C,D) 9(E,F,G) Contacts:…
…Information EPO-DS-30A-3W4P ExplosionProof Receptacle Features/Ratings Unit Type: ExplosionProof Single-Gang Receptacle w/ Disconnect Switch Class I, Div1 & 2 Groups B,C,D Dimensions: 9.06" x 14.06" x 13.95" Class II, Div1 & 2, Groups F,G Weight: - Class III Voltage: 600V AC/250V DC…
The Larson Electronics EPS-3P-30A-SPST ExplosionProof Three Pole Starter Switch is listed Class I Division 1 & 2 and Class II Division 1 & 2 and provides a safe and secure method for operators to use with contactors and magnetic starters to provide circuit selection and control for motors…
…HLSW-NFDS-SS-25A-EBC ExplosionProof Disconnect Switch Features/Ratings Unit Type: ExplosionProof Non-fused Disconnect Switch Class I, Division 2 Groups A,B,C,D Dimensions: 9.2" x 8.9" x 5.9" Class I, Zone 1 AEx de IIC T* Gb Weight: - Class II, Division 1 & 2, Groups E,F,G Rated Voltage:…
…HLSW-NFDS-SS-30A-EBC ExplosionProof Disconnect Switch Features/Ratings Unit Type: ExplosionProof Non-fused Disconnect Switch Class I, Division 2 Groups A,B,C,D Dimensions: 9.2" x 8.9" x 5.9" Class I, Zone 1 AEx de IIC T* Gb Weight: - Class II, Division 1 & 2, Groups E,F,G Rated Voltage:…
…ExplosionProof Disconnect Switch Ratings/Approvals Unit Type: ExplosionProof Disconnect Switch Class I, Division 2 Groups A,B,C,D Dimensions: 8.86" x 5.51" x 6.14" Class I, Zones 1 & 2 AEx de IIC, T6 Weight: 5.1 lbs Class II, Division 1 Groups E, F, G Rated Voltage: 690V Class II, Division 2…
…Switch Class I, Division 2 Groups A, B, C, D Dimensions: 1.2" Diameter Class I, Zone 1 AEx e IIC Gb / Ex e IIC Gb U Weight: 2 lbs Class II, Division 1 Groups E, F, G (Canada) Voltage Rating: 690V AC Class II, Division 2 Groups E, F, G Switch Type: 3-Position Selector Class III Contacts: (2) Normally…